Fujitsu General & O General AC Error Codes Explained

Find your code, understand what it means, then run a guided diagnosis.

Reviewed by the Quick Fix Force technical team · Technically reviewed 2026-08-20 · Content updated 2026-08-20

Error Code Finder

Look a code up against sourced manufacturer records. Codes we cannot source are not listed — a guessed meaning is worse than no meaning.

1. Which manufacturer?
2. What code is displayed?

Format does not matter — U4, U-4, u 4 and U04 all work.

Skip to all documented codes

Fujitsu General — sold across the UAE under the O General name as well — uses a colon-separated "E:xx" code format on current models, and a two-character format on older units. The two generations overlap in characters but not always in meaning, so the first step is identifying which format your unit displays. On wired remotes the display combines the indoor unit address with the fault code, which is why the reading is often longer than the code itself.

How do Fujitsu General (O General) error codes work?

Current models display E:00 to E:13 — a colon, then two characters identifying the fault. E:0 and E:01 are communication faults, E:02 to E:07 are indoor and outdoor sensor faults, E:08 is a power supply problem, E:09 is a drain float switch trip, and E:0C to E:0F cover discharge temperature. Older units use a two-character format (00, 01, 1A, 24) with its own table. On wired remotes the indoor unit address is shown as a prefix before the fault code.

Product families covered

  • Current models (E:xx format)

    Colon-separated codes on the indoor display or wired remote.

  • Legacy models (two-character format)

    Older splits and multis using hex-style two-character codes.

Where the code is displayed — and why it matters

The same fault can be labelled differently depending on which display you read it from, so identify the display before looking the code up.

Indoor unit display
Wall-mounted splits show the code on the front panel.
Wired remote controller
Displays the indoor unit address as a prefix followed by the fault code — the address is not part of the fault.
Wireless remote LED flash count
Some residential lines signal the fault by counting LED flashes instead of showing characters.

Fujitsu General code groups

On current E:xx models the second character narrows the fault:

E:0 / E:01
Communication — controller to indoor, or indoor to outdoor
E:02–E:07
Room and pipe sensor faults, open or short circuit
E:08
Power source connection or supply fault
E:09
Drain float switch activated
E:0A–E:0F
Outdoor air and discharge temperature faults
E:11–E:13
PCB compatibility, indoor fan and outdoor signal faults

How the families differ

  • The legacy two-character table and the current E:xx table are separate. A bare "13" on an old unit and "E:13" on a current one should each be read against their own table.
  • Legacy codes are documented with the letter O rather than a zero in several positions (O1, OA, OC, OE) — the character shown on the display decides which row applies.
  • On wired remotes the reading combines the indoor unit address with the fault code, so on a multi-split installation it also tells you which indoor unit reported the fault.

Fujitsu General current models (E:xx format)

Codes as displayed on current Fujitsu General and O General models. Severity is not stated in our source material for this brand, so no severity level is published.

Fujitsu General current models (E:xx format)
Code What it reports Applies to Severity Source
E:0 / E:00 Indicates indoor unit to remote controller communication fault Current models (E:xx format) B
E:01 Indicates indoor to outdoor unit communication fault Current models (E:xx format) B
E:02 Indicates room sensor open circuit Current models (E:xx format) B
E:03 Indicates room sensor short circuit Current models (E:xx format) B
E:04 Indicates indoor unit pipe sensor open circuit Current models (E:xx format) B
E:05 Indicates indoor unit pipe sensor short circuit Current models (E:xx format) B
E:06 Indicates outdoor unit pipe sensor open circuit Current models (E:xx format) B
E:07 Indicates outdoor unit pipe sensor short circuit Current models (E:xx format) B
E:08 Indicates power source connection failure or incorrect power supply Current models (E:xx format) B
E:09 Indicates float switch activated — drain problem, high water level Current models (E:xx format) B
E:0A Indicates outdoor air sensor open circuit Current models (E:xx format) B
E:0C Indicates discharge sensor open circuit Current models (E:xx format) B
E:0D Indicates discharge sensor short circuit Current models (E:xx format) B
E:0F Indicates high discharge temperature — contamination in the pipework or refrigerant shortage Current models (E:xx format) B
E:11 Indicates model or PCB compatibility abnormal Current models (E:xx format) B
E:12 Indicates indoor fan failure Current models (E:xx format) B
E:13 Indicates outdoor signal abnormal / communications issue Current models (E:xx format) B

Fujitsu General legacy models (two-character format)

Older splits and multis. This table must not be cross-read against the E:xx table.

Fujitsu General legacy models (two-character format)
Code What it reports Applies to Severity Source
OO Indicates indoor unit to remote control communication failure Legacy models (two-character format) B
O1 Indicates indoor to outdoor unit communication failure Legacy models (two-character format) B
O2 / O3 Indicates indoor air sensor open or closed circuit Legacy models (two-character format) B
O4 / O5 Indicates indoor pipe sensor open or closed circuit Legacy models (two-character format) B
O6 Indicates outdoor pipe sensor failure Legacy models (two-character format) B
O8 Indicates power source connection failure Legacy models (two-character format) B
O9 Indicates drain problem — float switch operated Legacy models (two-character format) B
OA Indicates outdoor air sensor failure Legacy models (two-character format) B
OC Indicates discharge sensor failure Legacy models (two-character format) B
OE Indicates outdoor high pressure or heatsink error Legacy models (two-character format) B
11 Indicates outdoor PCB failure Legacy models (two-character format) B
12 Indicates indoor fan failure Legacy models (two-character format) B
13 Indicates outdoor signal abnormal / indoor signal error Legacy models (two-character format) B
14 Indicates outdoor EEPROM failure Legacy models (two-character format) B
15 Indicates compressor temperature failure Legacy models (two-character format) B
16 Indicates pressure switch error Legacy models (two-character format) B
17 Indicates iPM error Legacy models (two-character format) B
18 Indicates cT (current transformer) error Legacy models (two-character format) B
1A Indicates compressor failure Legacy models (two-character format) B
1B Indicates outdoor fan failure Legacy models (two-character format) B
1C Indicates inverter-to-PCB communication failure Legacy models (two-character format) B
1D Indicates two-way valve sensor failure Legacy models (two-character format) B
1E Indicates expansion valve error Legacy models (two-character format) B
24 Indicates excessive high pressure protection in cooling Legacy models (two-character format) B
25 Indicates pFC circuit error Legacy models (two-character format) B
28 Indicates indoor heat exchanger temperature error Legacy models (two-character format) B
2C Indicates four-way valve abnormal Legacy models (two-character format) B

Before you act on a code

  • E:0F reports a high discharge temperature, which our source attributes to contamination in the pipework or a refrigerant shortage. Repeatedly restarting the unit through this fault risks the compressor.
  • E:08 is a power-supply fault. If it appears alongside a tripped breaker, leave the unit off and have the supply inspected rather than resetting repeatedly.
  • Fujitsu General VRF and J-series-specific variations are still in technical review and are not published here.

Corroborated across independent technical sources

How to identify your system

  1. Note whether the display shows a colon (E:01) or two plain characters (01) — that identifies the code generation.
  2. On a wired remote, note the full reading: the address prefix identifies which indoor unit reported the fault.
  3. Photograph the indoor unit's model label; O General and Fujitsu General units share the same code tables.

No code showing? Start from the symptom

Fujitsu General error codes — common questions

Are O General and Fujitsu General error codes the same?

Yes. O General is the brand name Fujitsu General's air conditioners are sold under in this region, and the same E:xx and legacy code tables apply. Read the code against the format shown on the display rather than the badge.

What does E:01 mean on a Fujitsu General AC?

E:01 is an indoor-to-outdoor unit communication fault. The indoor and outdoor boards are no longer exchanging valid signals — check first that the outdoor unit still has power, then the interconnecting wiring, then the boards.

What does E:09 mean?

E:09 means the float switch has activated because the condensate water level is too high. In Dubai this is usually a blocked or badly sloped drain line, and the unit stops deliberately to avoid overflowing into the room.

Why does my remote show numbers before the error code?

On wired remotes Fujitsu General displays the indoor unit address as a prefix to the fault code. The prefix identifies which indoor unit reported the fault; only the suffix is the code you look up.

Need this looked at properly?

Call or send a photo on WhatsApp and we will tell you whether it needs an inspection, and what the work involves, before anyone travels.