York AC Error Codes: What They Mean & What to Do

Find your code, understand what it means, then run a guided diagnosis.

Reviewed by the Quick Fix Force technical team · Technically reviewed 2026-08-20 · Content updated 2026-08-20

Error Code Finder

Look a code up against sourced manufacturer records. Codes we cannot source are not listed — a guessed meaning is worse than no meaning.

1. Which manufacturer?
2. What code is displayed?

Format does not matter — U4, U-4, u 4 and U04 all work.

Skip to all documented codes

York organises its codes by letter, and the letter tells you which side of the system reported the fault: E codes are indoor-side and control faults, F codes are outdoor, inverter and sensor faults, and P codes are protection trips that stop the system to prevent damage. Multi-split and commercial installations add a separate CCM network fault series, which belongs to the building-controls domain rather than to a single unit.

How do York AC error codes work?

York E codes cover indoor-side and control faults such as sensors, EEPROM and indoor–outdoor communication. F codes cover the outdoor unit — IPM module, compressor current, discharge temperature, fans and outdoor sensors. P codes are protection trips such as coil freeze-up, high discharge pressure and compressor overcurrent. On multi-split and commercial systems, 00# to 03# codes report CCM central-controller communication faults instead.

Product families covered

  • Split / inverter / multi-split

    The consolidated E / F / P / T / H code table.

  • CCM network controller

    00# to 03# communication faults between the CCM and the main PCB, NIM module, function module or PC gateway.

Where the code is displayed — and why it matters

The same fault can be labelled differently depending on which display you read it from, so identify the display before looking the code up.

Indoor unit display
Shows the E, F or P code on residential splits.
Wired wall controller
Shows the same code set, often with the affected zone on multi-split systems.
CCM central controller
Shows the 00# to 03# network fault series — a different fault domain from the unit codes.

York code letters

The letter identifies the fault area before you know the exact code:

E
Indoor-side, sensor, memory and communication faults
F
Outdoor unit, inverter, compressor and outdoor sensor faults
P
Protection trips — pressure, temperature, overcurrent
T / H
Sensor circuit faults and control-network faults
00#–03#
CCM central controller network faults (multi-split / commercial)

How the families differ

  • A single split reports faults for one indoor/outdoor pair, so an E7 communication fault narrows to wiring, terminations or the boards at either end.
  • Multi-split and commercial systems add the CCM network series, where a fault can affect a whole group of units without any single unit being defective.
  • York's VRF-specific YVAM and YMAE code sets were not isolated in our source material and are therefore not published here.

Documented York split, inverter and multi-split codes

Our York source is one comprehensive independent technical compilation checked for internal consistency rather than an official York service PDF — confirm against your model's documentation before repair decisions.

Documented York split, inverter and multi-split codes
Code What it reports Applies to Severity Source
E0 Is reported to indicate reverse phase sequence or missing phase in the power supply Split / inverter / multi-split High C
E1 Is reported to indicate room temperature sensor failure or out-of-range reading Split / inverter / multi-split Moderate C
E2 Is reported to indicate t1 indoor room temperature sensor hardware malfunction Split / inverter / multi-split Moderate C
E3 Is reported to indicate indoor unit T2A coil / pipe temperature sensor hardware fault Split / inverter / multi-split Moderate C
E4 Is reported to indicate indoor unit EEPROM configuration memory failure or checksum error Split / inverter / multi-split High C
E5 Is reported to indicate t3 coil temperature sensor hardware malfunction Split / inverter / multi-split Moderate C
E6 Is reported to indicate outdoor inverter drive board zero-crossing detection circuit fault Split / inverter / multi-split High C
E7 Is reported to indicate loss of communication between the indoor and outdoor unit Split / inverter / multi-split High C
E8 Is reported to indicate indoor fan motor speed feedback loss or control error Split / inverter / multi-split Moderate C
E9 Is reported to indicate loss of communication between the main control PCB and the display board Split / inverter / multi-split Moderate C
E14 Is reported to indicate indoor blower fan motor failure or speed control fault Split / inverter / multi-split Moderate C
EC Is reported to indicate system diagnostic clear command / malfunction reset Split / inverter / multi-split Low C
EE Is reported to indicate water level switch or condensate drain fault Split / inverter / multi-split Moderate C
EF Is reported to indicate unspecified miscellaneous system malfunction Split / inverter / multi-split Low C
F0 Is reported to indicate system overload protection trip Split / inverter / multi-split High C
F1 Is reported to indicate outdoor IPM power module thermal or current protection trip Split / inverter / multi-split High C
F2 Is reported to indicate outdoor compressor operating current exceeding its rated limit Split / inverter / multi-split High C
F3 Is reported to indicate loss of communication between the IPM drive module and the outdoor PCB Split / inverter / multi-split High C
F4 Is reported to indicate compressor discharge line high-temperature protection trip Split / inverter / multi-split High C
F5 Is reported to indicate outdoor DC fan motor speed feedback or drive control fault Split / inverter / multi-split Moderate C
F6 Is reported to indicate outdoor ambient air temperature sensor hardware fault Split / inverter / multi-split Moderate C
F7 Is reported to indicate outdoor suction line temperature sensor hardware fault Split / inverter / multi-split Moderate C
F8 Is reported to indicate outdoor DC fan motor electrical or mechanical failure Split / inverter / multi-split High C
F9 Is reported to indicate indoor front auto-lifting panel position fault (cassette type) Split / inverter / multi-split Low C
F11 Is reported to indicate outdoor compressor speed or operational parameter deviation fault Split / inverter / multi-split High C
F12 Is reported to indicate outdoor unit EEPROM memory corruption or checksum failure Split / inverter / multi-split High C
F19 Is reported to indicate outdoor unit incoming AC supply voltage out-of-range trip Split / inverter / multi-split High C
F21 Is reported to indicate outdoor defrost temperature sensor hardware fault Split / inverter / multi-split Moderate C
F22 Is reported to indicate outdoor unit incoming AC line supply overcurrent trip Split / inverter / multi-split High C
F23 Is reported to indicate compressor single-phase electrical overcurrent protection trip Split / inverter / multi-split High C
F25 Is reported to indicate outdoor discharge line temperature sensor hardware fault Split / inverter / multi-split Moderate C
F28 Is reported to indicate station loop detection error on the communication network Split / inverter / multi-split Moderate C
P0 Is reported to indicate indoor evaporator coil freeze-up / low-temperature protection trip Split / inverter / multi-split Moderate C
P1 Is reported to indicate indoor anti-cold-blow / defrost protection active Split / inverter / multi-split Low C
P2 Is reported to indicate outdoor condenser coil high-temperature protection trip Split / inverter / multi-split High C
P3 Is reported to indicate compressor shell or internal motor temperature protection trip Split / inverter / multi-split High C
P6 Is reported to indicate high refrigerant discharge pressure safety cut-out trip Split / inverter / multi-split High C
P7 Is reported to indicate incoming power supply loss of phase or over-voltage protection Split / inverter / multi-split High C
P8 Is reported to indicate compressor motor electrical overcurrent protection trip Split / inverter / multi-split High C
PF Is reported to indicate unspecified system protection shutdown trip Split / inverter / multi-split Moderate C
T3 Is reported to indicate t3 temperature sensor circuit hardware malfunction Split / inverter / multi-split Moderate C
T4 Is reported to indicate temperature sensor circuit hardware malfunction Split / inverter / multi-split Moderate C
H1 Is reported to indicate system control network communication bus malfunction Split / inverter / multi-split High C
H2 Is reported to indicate host outdoor unit detecting a missing outdoor module on the system bus Split / inverter / multi-split High C
H3 Is reported to indicate host outdoor unit detecting an unconfigured outdoor module on the network Split / inverter / multi-split Moderate C

York CCM network controller faults

A network and building-controls fault domain rather than a refrigerant or electrical fault in one unit.

York CCM network controller faults
Code What it reports Applies to Severity Source
00# / 01# / 02# / 03# Is reported to indicate cCM controller communication faults with, respectively, the main PCB, the NIM module, the function module and the PC gateway CCM network controller Moderate C

Before you act on a code

  • P-series codes are protection trips: the system stopped deliberately, so clearing the code without finding the cause invites repeat failures.
  • E0 and P7 indicate incoming supply phase problems — an electrical supply issue, not an AC fault, and it should be checked by a qualified electrician.
  • York VRF-specific code sets are still in technical review and are not published here.

Secondary source only

How to identify your system

  1. Note the exact code and whether it appeared on the indoor unit, a wall controller or a central CCM controller.
  2. Note whether one indoor unit or several run from the outdoor unit.
  3. Photograph the indoor unit's model label before contacting a technician.

No code showing? Start from the symptom

York error codes — common questions

What does York E7 mean?

E7 is a loss of communication between the indoor and outdoor unit. The fault is in the link — interconnecting wiring, terminations, or the control boards at either end — rather than in the cooling circuit. One power cycle is reasonable; a code that returns needs inspection.

What does York EE mean?

EE reports a water level switch or condensate drain fault. In Dubai this is a commonly reported summer fault, because high humidity produces a large volume of condensate and a partially blocked drain fills the tray faster than it can empty.

Is York F1 serious?

F1 is an IPM power module thermal or current protection trip on the outdoor unit. It is a high-severity electronics fault, so the unit should be left off and inspected rather than reset repeatedly.

My whole floor's York units show faults at once — why?

On multi-split and commercial installations the CCM network series (00# to 03#) reports communication faults between the central controller and the boards or gateways it manages. A single network or gateway fault can therefore surface across many units at the same time.

Need this looked at properly?

Call or send a photo on WhatsApp and we will tell you whether it needs an inspection, and what the work involves, before anyone travels.