AC Error Codes · Hisense
Hisense AC Error Codes: What They Mean & What to Do
Find your code, understand what it means, then run a guided diagnosis.
Error Code Finder
Look a code up against sourced manufacturer records. Codes we cannot source are not listed — a guessed meaning is worse than no meaning.
Hisense runs two entirely separate code architectures. Residential splits report plain two-digit numbers from 01 to 97, and PAC light-commercial units report E-prefixed codes. A number and an E code are never the same fault system, so the first question is which line your unit belongs to. Hisense also has a distinctive repeat-fault state: EE is not a fault of its own but a compressor protection triggered by other codes recurring.
How do Hisense AC error codes work?
On residential splits, Hisense uses two-digit numeric codes: roughly 01–19 for outdoor, inverter and compressor faults, and 33–97 for indoor sensors, communication, fan, pressure and valve faults. PAC light-commercial units instead use E0 to E5 for indoor sensors, communication, compressor overcurrent and outdoor fan failure. EE on a split is a compressor protection state caused by repeated faults within six hours.
Product families covered
-
Residential split (numeric)
Two-digit codes from 01 to 97 plus the EE protection state.
-
PAC series (light commercial)
A separate E0–E5 code set — not comparable to the numeric table.
Where the code is displayed — and why it matters
The same fault can be labelled differently depending on which display you read it from, so identify the display before looking the code up.
- Indoor unit display
- Residential splits show the two-digit number on the front panel.
- Wired remote controller
- Shows the same numeric code; code 35 specifically reports a fault in this link.
- PAC unit controller
- Shows the E-prefixed light-commercial code set.
Hisense numeric code ranges
On residential splits the range indicates roughly where the fault sits:
- 01–19
- Outdoor, inverter, compressor and supply faults
- 21–49
- Sensors, communication, drain, fan and pressure faults
- 54–97
- Inverter feedback, controller network, valve and shutdown protections
- E0–E5
- PAC light-commercial set — a separate architecture
How the families differ
- A two-digit number and an E code come from different Hisense systems and must never be cross-read.
- Several numeric codes are documented with two alternative meanings depending on the model, and both are published rather than one being chosen.
- Hisense VRF-specific codes and ducted/cassette variance were not covered by our source material and are not published here.
Hisense residential split — numeric codes
From two independently produced full-list compilations with strong mutual consistency. Severity is not given in our Hisense source material, so no severity level is published.
| Code | What it reports | Applies to | Severity | Source |
|---|---|---|---|---|
| 01 | Indicates outdoor EEPROM parameter error, or (alternate) indoor protection device / float switch activated | Residential split (numeric) | — | B |
| 02 | Indicates compressor start failure, or outdoor coil sensor short / open circuit | Residential split (numeric) | — | B |
| 03 | Indicates voltage transformer issue, or signal loss between the indoor and outdoor unit | Residential split (numeric) | — | B |
| 04 | Indicates current transformer issue, or signal fault between the inverter circuit and the control circuit | Residential split (numeric) | — | B |
| 05 | Indicates iPM module protection, or incorrect power-supply phase sequence | Residential split (numeric) | — | B |
| 06 | Indicates over- or under-voltage control, or abnormal inverter compressor voltage | Residential split (numeric) | — | B |
| 07 | Indicates communication trouble, or reduction of discharge gas superheat from the compressor | Residential split (numeric) | — | B |
| 08 | Indicates current overload control, or abnormally high compressor discharge temperature | Residential split (numeric) | — | B |
| 09 | Indicates maximum current control | Residential split (numeric) | — | B |
| 10 | Indicates communication trouble between the outdoor unit and the driver unit | Residential split (numeric) | — | B |
| 11 | Indicates outdoor EEPROM error, or indoor air-inlet sensor fault | Residential split (numeric) | — | B |
| 12 | Indicates indoor air-outlet sensor fault | Residential split (numeric) | — | B |
| 13 | Indicates compressor exhaust temperature too high control, or indoor liquid-pipe sensor fault | Residential split (numeric) | — | B |
| 14 | Indicates outdoor ambient temperature sensor issue, or indoor gas-pipe sensor fault | Residential split (numeric) | — | B |
| 15 | Indicates compressor housing temperature control | Residential split (numeric) | — | B |
| 16 | Indicates antifreeze / overload control | Residential split (numeric) | — | B |
| 17 | Indicates exhaust temperature sensor short or open circuit (PFC protection on some models) | Residential split (numeric) | — | B |
| 18 | Indicates dC compressor fails to start, or power input AC voltage too low or too high | Residential split (numeric) | — | B |
| 19 | Indicates dC compressor out of step, or indoor fan motor protection activated | Residential split (numeric) | — | B |
| 21 | Indicates outdoor high-pressure sensor fault | Residential split (numeric) | — | B |
| 33 | Indicates room temperature sensor issue | Residential split (numeric) | — | B |
| 34 | Indicates indoor coil temperature sensor issue | Residential split (numeric) | — | B |
| 35 | Indicates communication issue between the wired remote and the indoor unit | Residential split (numeric) | — | B |
| 36 | Indicates communication issue between the indoor and outdoor unit | Residential split (numeric) | — | B |
| 37 | Indicates water overflowed the pump | Residential split (numeric) | — | B |
| 38 | Indicates indoor EEPROM issue | Residential split (numeric) | — | B |
| 39 | Indicates indoor fan motor operation abnormal, or non-inverter compressor abnormal current | Residential split (numeric) | — | B |
| 41 | Indicates zero-crossing detection failure | Residential split (numeric) | — | B |
| 44 | Indicates low-pressure sensor fault | Residential split (numeric) | — | B |
| 45 | Indicates iPM fault | Residential split (numeric) | — | B |
| 46 | Indicates iPM communication fault | Residential split (numeric) | — | B |
| 47 | Indicates exhaust temperature too high — shutdown | Residential split (numeric) | — | B |
| 48 / 49 | Indicates outdoor DC fan fault | Residential split (numeric) | — | B |
| 54 | Indicates inverter PCB heatsink temperature abnormal | Residential split (numeric) | — | B |
| 55 | Indicates no feedback signal from the inverter PCB | Residential split (numeric) | — | B |
| 57 | Indicates outdoor fan protection activated | Residential split (numeric) | — | B |
| 60 / 64 | Indicates signal loss between the central controller and the outdoor unit (running / stopped) | Residential split (numeric) | — | B |
| 73 | Indicates panel board EEPROM error | Residential split (numeric) | — | B |
| 80 | Indicates display board fault | Residential split (numeric) | — | B |
| 81 | Indicates room sensor error | Residential split (numeric) | — | B |
| 83 | Indicates sensor error (unspecified) | Residential split (numeric) | — | B |
| 90 | Indicates forced expansion valve operation | Residential split (numeric) | — | B |
| 91 | Indicates iPM temperature too high — shutdown | Residential split (numeric) | — | B |
| 92 | Indicates compression ratio too large — stop | Residential split (numeric) | — | B |
| 97 | Indicates four-way valve commutation failure | Residential split (numeric) | — | B |
| EE | Indicates compressor protection code, triggered by repeated 02, 07, 08, 39, 43, 44, 45 or 47 events within 6 hours | Residential split (numeric) | — | B |
Hisense PAC series (light commercial) codes
A separate E-code architecture used on the PAC light-commercial line.
| Code | What it reports | Applies to | Severity | Source |
|---|---|---|---|---|
| E0 | Indicates indoor unit ambient temperature sensor error | PAC series (light commercial) | — | B |
| E1 | Indicates indoor unit coil temperature sensor error | PAC series (light commercial) | — | B |
| E2 | Indicates indoor unit communication error | PAC series (light commercial) | — | B |
| E3 | Indicates outdoor unit communication error | PAC series (light commercial) | — | B |
| E4 | Indicates compressor overcurrent protection | PAC series (light commercial) | — | B |
| E5 | Indicates outdoor unit fan motor failure | PAC series (light commercial) | — | B |
Before you act on a code
- EE on a split is a protection state, not the root fault: the code that keeps repeating (for example 02, 08 or 45) is what needs diagnosis.
- Codes reporting IPM, phase sequence or supply voltage are electrical faults — leave the unit off and have them inspected.
- Hisense VRF and ducted-specific code tables are still in technical review.
Corroborated across independent technical sources
How to identify your system
- Note whether the display shows a plain number or an E code — that decides which table applies.
- Note where you read it: indoor unit, wired controller or a central controller.
- Photograph the indoor unit's model label, as several numeric codes have model-dependent alternatives.
No code showing? Start from the symptom
Hisense error codes — common questions
What does Hisense EE mean?
EE is a compressor protection code, triggered when certain faults — 02, 07, 08, 39, 43, 44, 45 or 47 — recur within six hours. Clearing EE without diagnosing the recurring code simply resets the counter while the underlying fault remains.
What does Hisense error 36 mean?
36 is a communication problem between the indoor and outdoor unit. The fault sits in the interconnecting wiring, the terminations, or the boards at either end rather than in the cooling circuit.
Why do some Hisense codes have two meanings?
Because Hisense used the same numbers differently across model lines, and our sources document both. Rather than choose, we publish both documented meanings and flag that the model label resolves it.
Is a Hisense PAC E4 the same as split code 04?
No. The PAC light-commercial E-code set and the residential split numeric set are separate architectures. PAC E4 is compressor overcurrent protection; split code 04 is a current transformer or inverter-circuit signal fault.