Gree AC Error Codes: What They Mean & What to Do
Find your code, understand what it means, then run a guided diagnosis.
Error Code Finder
Look a code up against sourced manufacturer records. Codes we cannot source are not listed — a guessed meaning is worse than no meaning.
Gree uses a letter-plus-digit code system where the letter identifies the type of event: E codes are system protections, F codes are sensor faults and frequency limits, H codes are compressor and power-module protections, and P, U and L codes are reported by the outdoor inverter drive board. Gree is also the OEM behind several other names sold in the UAE, so the same code layout often appears on rebadged units — but only the Gree table should be read against a Gree brand plate.
How do Gree error codes work?
The letter tells you the fault family: E = system protection (pressure, communication, over-current), F = sensor faults and frequency limiting, H = compressor and power-module protection, C = PCB configuration, and L, P and U = outdoor inverter drive faults. The digit identifies the specific fault. Codes appear on the indoor unit display or handset; drive-board codes are read on the outdoor board. Some codes, such as H1 (defrosting), report a normal operating state rather than a fault.
Product families covered
-
Residential split / multi-split
E, F, H and C codes shown on the indoor display or remote.
-
Ducted
Shares the indoor-displayed code set.
-
Outdoor inverter drive board
P, U, L, HC, EU and oE codes reported by the drive board — a separate family from the indoor codes.
Where the code is displayed — and why it matters
The same fault can be labelled differently depending on which display you read it from, so identify the display before looking the code up.
- Indoor unit display
- Wall-mounted splits flash the code on the front panel display.
- Wireless remote / handset
- Some models mirror the active code on the handset screen.
- Outdoor inverter drive board
- P / U / L / oE drive codes are read on the outdoor board, not the room display.
Gree code letter families
The letter narrows the fault before you know the exact code:
- E
- System protections — pressure, communication, over-current, water level
- F
- Sensor faults and protective frequency limiting
- H
- Compressor, power-module and system protections (H1 = defrost status)
- C
- PCB configuration (jumper cap)
- L
- Startup, fan-motor and compressor-phase faults
- P
- Drive-board voltage, current and IPM faults
- U
- Compressor phase / rotation and AC detection faults
How the families differ
- Indoor-displayed E, F and H codes describe what the system protected itself against; the P, U and L drive codes describe why the inverter board stopped driving the compressor.
- A frequency-limit code (F6, F8, F9, FA, H0) is not a hard fault — the unit is deliberately reducing output to stay inside a limit, which in Dubai summer often means the condenser cannot reject heat fast enough.
- Gree U4 has nothing to do with Daikin U4. Codes are only ever read against the manufacturer on the brand plate.
Gree indoor-displayed codes (split, multi-split, ducted)
Codes read from the indoor display or handset. Severity follows the source research: protections marked high stop the system to prevent damage, moderate codes usually allow limited running, and status codes such as H1 are not faults at all.
| Code | What it reports | Applies to | Severity | Source |
|---|---|---|---|---|
| E1 | Indicates high-pressure protection (refrigerant system) | Split / Multi-split · Ducted | High | B |
| E2 | Indicates anti-freezing protection (indoor coil, cooling mode) | Split / Multi-split · Ducted | Moderate | B |
| E3 | Indicates low refrigerant / low-pressure protection | Split / Multi-split · Ducted | High | B |
| E4 | Indicates compressor discharge high-temperature protection | Split / Multi-split · Ducted | High | B |
| E5 | Indicates over-current protection | Split / Multi-split · Ducted | High | B |
| E6 Diagnose | Indicates communication failure between indoor and outdoor unit | Split / Multi-split · Ducted | High | B |
| E7 | Is reported to indicate mode conflict (multi-split systems) | Split / Multi-split · Ducted | Moderate | C |
| E8 | Indicates anti-high-temperature protection / evaporator high temperature | Split / Multi-split · Ducted | Moderate | B |
| E9 | Is reported to indicate indoor unit water pump / water level problem | Split / Multi-split · Ducted | Moderate | C |
| EE | Is reported to indicate loading EEPROM malfunction | Split / Multi-split · Ducted | High | C |
| F0 | Indicates refrigerant leakage protection | Split / Multi-split · Ducted | High | B |
| F1 | Indicates indoor ambient sensor open or short circuit | Split / Multi-split · Ducted | Moderate | B |
| F2 | Indicates indoor tube (evaporator) sensor open or short circuit | Split / Multi-split · Ducted | Moderate | B |
| F3 | Indicates outdoor ambient temperature sensor open or short circuit | Split / Multi-split · Ducted | Moderate | B |
| F4 | Indicates outdoor tube (condenser) sensor open or short circuit | Split / Multi-split · Ducted | Moderate | B |
| F5 | Indicates exhaust / discharge sensor open or short circuit | Split / Multi-split · Ducted | Moderate | B |
| F6 | Is reported to indicate overload limit / frequency drop | Split / Multi-split · Ducted | Moderate | C |
| F8 | Is reported to indicate over-current limit / frequency drop | Split / Multi-split · Ducted | Moderate | C |
| F9 | Is reported to indicate high exhaust temperature limit / frequency drop | Split / Multi-split · Ducted | Moderate | C |
| FA | Is reported to indicate over tube temperature frequency drop | Split / Multi-split · Ducted | Moderate | C |
| FC | Is reported to indicate door malfunction | Split / Multi-split · Ducted | Low | C |
| FE | Is reported to indicate compressor overload sensor malfunction | Split / Multi-split · Ducted | High | C |
| FH | Is reported to indicate anti-freezing limit / frequency drop | Split / Multi-split · Ducted | Moderate | C |
| H0 | Is reported to indicate anti-high-temperature frequency drop (heating mode) | Split / Multi-split · Ducted | Moderate | C |
| H1 | Indicates defrosting — an operating status, not necessarily a fault | Split / Multi-split · Ducted | Low | B |
| H2 | Is reported to indicate static clearing / dust protection | Split / Multi-split · Ducted | Low | C |
| H3 | Indicates compressor overload protection | Split / Multi-split · Ducted | High | B |
| H4 | Indicates system abnormal protection | Split / Multi-split · Ducted | High | B |
| H5 | Indicates iPM (power module) protection | Split / Multi-split · Ducted | High | B |
| H6 | Indicates indoor fan motor blocked or no feedback | Split / Multi-split · Ducted | Moderate | B |
| H7 | Indicates compressor loss-of-step / desynchronisation protection | Split / Multi-split · Ducted | High | B |
| HE | Is reported to indicate compressor demagnetisation protection | Split / Multi-split · Ducted | High | C |
| C5 | Indicates jumper cap malfunction or protection | Split / Multi-split · Ducted | Moderate | B |
| L3 | Is reported to indicate outdoor DC fan motor malfunction | Split / Multi-split · Ducted | High | C |
| U7 | Indicates four-way (reversing) valve reversal abnormal | Split / Multi-split · Ducted | High | B |
| U8 | Is reported to indicate disconnection of exhaust / discharge temperature sensor | Split / Multi-split · Ducted | Moderate | C |
| U9 | Is reported to indicate aC power zero-voltage detection error | Split / Multi-split · Ducted | Moderate | C |
| b5 / b7 | Is reported to indicate inlet or outlet tube sensor malfunction | Split / Multi-split · Ducted | Moderate | C |
Gree outdoor inverter drive board codes
Reported by the outdoor drive board. These are electrical and inverter-level faults — the outdoor unit's power side must be isolated by a technician before any inspection.
| Code | What it reports | Applies to | Severity | Source |
|---|---|---|---|---|
| ee | Is reported to indicate outdoor drive memory chip error | Outdoor inverter drive board | High | C |
| EU | Is reported to indicate iPM over-temperature limit / frequency drop | Outdoor inverter drive board | High | C |
| HC | Is reported to indicate pFC protection | Outdoor inverter drive board | High | C |
| Lc | Is reported to indicate startup failure | Outdoor inverter drive board | High | C |
| Ld | Is reported to indicate compressor loss-of-phase protection | Outdoor inverter drive board | High | C |
| LE | Is reported to indicate compressor locked-rotor protection | Outdoor inverter drive board | High | C |
| PL / P0 | Indicates low PN (DC bus) voltage protection or drive module reset problem | Outdoor inverter drive board | High | B |
| P5 | Is reported to indicate over compressor phase current protection | Outdoor inverter drive board | High | C |
| P6 | Is reported to indicate communication failure between main board and driver board | Outdoor inverter drive board | High | C |
| P7 | Is reported to indicate iPM sensor circuit malfunction | Outdoor inverter drive board | High | C |
| P8 | Is reported to indicate iPM high-temperature protection | Outdoor inverter drive board | High | C |
| PA | Is reported to indicate aC current protection (input side) | Outdoor inverter drive board | High | C |
| Pc | Is reported to indicate current-detection circuit or current sensor malfunction | Outdoor inverter drive board | High | C |
| PH | Is reported to indicate over-voltage protection (PN / DC bus) | Outdoor inverter drive board | High | C |
| PU | Is reported to indicate capacitor charge malfunction | Outdoor inverter drive board | High | C |
| U1 | Indicates compressor phase current detection circuit malfunction / DC bus voltage abnormal | Outdoor inverter drive board | High | B |
| U2 | Is reported to indicate compressor protection against loss of phase | Outdoor inverter drive board | High | C |
| U3 | Is reported to indicate pN voltage drop protection | Outdoor inverter drive board | High | C |
| U4 | Is reported to indicate compressor reverse-rotation protection | Outdoor inverter drive board | High | C |
| U5 | Is reported to indicate aC current-detection circuit malfunction | Outdoor inverter drive board | Moderate | C |
| oE | Is reported to indicate pFC module temperature protection or sensor malfunction | Outdoor inverter drive board | High | C |
Full guides for high-demand Gree codes
Codes without their own guide are answered in the table above. We only give a code its own page when there is genuinely more to say than a table row can hold.
Before you act on a code
- Several drive-board codes (P, U, L series) come from a single technical compilation in our research pass rather than an official Gree service manual — verify against your model's documentation before parts are replaced.
- Do not clear a high-severity protection code by repeatedly switching the unit off and on. E1, E3, E4, E5, H3, H4, H5 and H7 all indicate the system stopped to protect itself.
- Gree-built units are sold under other brand names in the UAE. Read the code against the brand on the plate, not the brand on the invoice.
Corroborated across independent technical sources
How to identify your system
- Note the exact code and whether it appeared on the indoor display, the handset, or the outdoor drive board.
- Photograph the indoor unit's model label — the label settles which code family applies.
- Note whether the unit stops completely, or keeps running weakly (a frequency-limit code rather than a protection trip).
No code showing? Start from the symptom
Gree error codes — common questions
What does Gree E6 mean?
E6 indicates a communication failure between the indoor and outdoor unit — the two boards are no longer exchanging valid signals, so the system cannot run cooling. The usual causes are a loss of power to the outdoor unit, damaged interconnecting wiring, or a failed control board.
Is a Gree E1 or E3 code serious?
Both are high-severity refrigerant-circuit protections: E1 is high-pressure protection and E3 is low-pressure or low-refrigerant protection. The unit stops to protect the compressor. Neither should be repeatedly reset — the underlying pressure problem needs diagnosis.
Why does my Gree AC show a code only in the afternoon?
Protective frequency-limit and high-pressure codes are load-related. In Dubai's peak summer temperatures a dirty condenser, restricted airflow around the outdoor unit or a marginal refrigerant charge shows up first at the hottest part of the day, then clears as ambient temperature drops.
Is H1 on a Gree AC a fault?
No. H1 indicates the unit is running a defrost cycle, which is a normal operating state rather than a fault. If the unit spends long periods in defrost, or never returns to cooling, that is worth diagnosing.